New Handheld ECG/NIBP/SPO2/PR Patient Monitor PM-60D

New Handheld ECG/NIBP/SPO2/PR Patient Monitor PM-60D from Getbetterlife.com

By: Getbetterlife.com  10/15/2009
Keywords: Medical Devices

 New Handheld ECG/NIBP/SPO2/PR Patient Monitor PM-60D Introduction: ■ Routine Check Mode and         Continuous Monitoring Mode ■ Data Graph and Trend Table         Review ■ Rich Analysis Report ■ Perfect Mount Solution ■ Convenient operation by touch screen ■ Large SD card memory for more than         2000 patient cases storage ■ Sync with PC based Sofrware (WinXP and WinVista) Performance Specifications: ■ Display:3.5" Color TFT ■ Resolution:320x240 ■ Display Mode:Standard face, Waveform face, SPO2 view,         ECG view, BigNum view                   ■ Indicator:Power indicator light, Alarm sound, Pluse tone ■ Interface:One dual-purpose socket for connecting sensors          and communication cables ■ Power Supply:DC 5V, <500MA ■ Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours  ■ for continous working.10 hours for standby mode ■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time          96 hours. ■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000          items. ■ Alarm:Ajustable High and Low limits. Three level au        dible and vistual alarm  ■ User Configuration:All the color of parameters and waves         can be set according to user's willing Technical specifications: ■ Safety ■ Meet the requirment of IEC60601 series ■ Type of Protection:Class II with internal electirc power         supply ■ Degree of Protection:BF ■ Dimention and Weight ■ Dimention:92(W)x82(H)x22(D)mm ■ Weight:136g(with battery) ■ Operation Environment: ■ Temperature:0℃~ +40℃ ■ Humidity:15% ~ 95% ■ Storage Environment: ■ Temperature:-20℃~ +60℃ ■ Humidity:10% ~ 95%          ■ Patient Range ■ Neonate ,Pediatric and  Adult SPO2: ■ Measurement Range:0 ~ 100% ■ Resolution:1% ■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)                   ±3%(70%~100%, Neonate, non-motion)                 0% ~ 69% unspecified ■ Alarm Range:0% ~ 100% ■ Refreshing Rate:1s Pulse Rate: ■ Measurement Range:25 ~ 250 bpm ■ Resolution:1bpm ■ Accuracy:± bpm (non-motion) ■ Alarm Range:25 ~ 250 bmp ■ Refreshing Rate:1s ECG: ■ Lead mode:3-lead or 5-lead ■ Lead selection: I, II, III, AVR, AVL, AVF, V ■ HR range:15 ~ 300 bpm ■ ECG Waveform:2 channals ■ Accuracy:±2bpm or ±2%, which is greater ■ S-T segment detection, range: -2.0mv ~ +2.0mv ■ Arrhythmia analysis: 13 kinds of arrhythmia ■ Alarm Range:15 ~ 300 bpm NIBP: ■ Method:Oscillometry ■ Mode:Manual/Auto/Contiuous ■ Measurement Range:25 ~ 260mmHg ■ Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90         minutes ■ Resolution:1mmHg ■ Overpressure Protection: 300mmHg ■ Alarm range:25 ~260mmHg

Keywords: Medical Devices